Quick answer: Running watts is what an appliance uses once it is running; starting (surge) watts is the short burst motors and compressors need to start. A Zoeller M53 sump pump runs at about 1,115 VA but needs about 2,980 VA to start. Add all running watts, then add the largest single starting surge.
Specifications used in this guide
| Item | Figure |
|---|---|
| Sump pump (Zoeller M53) | 9.7 A running (about 1,115 VA at 115 V); 25.9 A starting (about 2,980 VA, listing) |
| Honda EU2200i | 1,800 W rated, 2,200 W maximum |
| Westinghouse WGen9500 | 9,500 W running, 12,500 W peak (gasoline) |
| EcoFlow DELTA 2 Max | 2,400 W continuous, 4,800 W surge |
| 8,000 BTU window AC (Frigidaire FFRE083WAE) | 670 W cooling (plus compressor start) |
| 1,000 W microwave (Magic Chef MCM1110) | 1,000 W output, about 1,500 W input |
| Electric kettle (Hamilton Beach 40880) | 1,500 W (no motor surge) |
Two numbers on every generator
Running watts, also called rated or continuous watts, is the power a device uses once it is up and running, or the power a generator can supply all the time. Starting watts, also called surge or peak watts, is the extra burst some devices need for a few seconds when they switch on, or the short burst a generator or power station can deliver.
A real example: a sump pump
The Zoeller M53 draws 9.7 A while running, about 1,115 VA at 115 V. A listing for the same pump gives 25.9 starting amps, about 2,980 VA, roughly 2.7 times the running figure, for a moment. That start-up burst, not the running load, is what usually trips an undersized generator.
Why motors surge
In an electric motor, copper stator coils create a magnetic field that drags the rotor around. At standstill the rotor is not spinning yet, so the coils draw a large current; as the rotor speeds up, the current falls to the running level. Motor nameplates list amps, and manuals may list locked rotor amps (LRA), the current at standstill.
Which appliances surge, and which do not
Anything with a motor or compressor surges: refrigerators, freezers, air conditioners, sump and well pumps, washers and dehumidifiers. Heating appliances such as space heaters, kettles and slow cookers simply heat a wire, so their running and starting watts are about the same. Microwaves are a different trap: a 1,000 W model is rated by cooking output and pulls about 1,500 W from the outlet; always plan with input power.
Generator and power station ratings
Honda lists the EU2200i at 1,800 W rated and 2,200 W maximum. Westinghouse lists the WGen9500 at 9,500 W running and 12,500 W peak. The EcoFlow DELTA 2 Max is rated 2,400 W continuous with a 4,800 W surge, enough for the M53’s roughly 2,980 VA start.
The formula
Add the running watts of everything that will run at the same time, then add the extra starting watts of only the biggest motor, because motors rarely start at the same second. Example: sump pump, window AC, microwave, TV, CPAP and LED lights run at about 3,500 W; the pump’s extra start of about 1,865 W makes a peak of about 5,400 W. Start the biggest motor first with nothing else running, and ask the maker or an HVAC technician whether a soft-start device suits your air conditioner. If you only know amps, watts are roughly amps x 120 V.
Key numbers at a glance
| Item | Figure | Note |
|---|---|---|
| Sump pump running (9.7 A) | about 1,115 VA | Zoeller M53 |
| Sump pump starting (25.9 A) | about 2,980 VA | about 2.7x running |
| Example list running / peak | about 3,500 / 5,400 W | Add biggest surge only |
Power station run-time estimates
Battery estimates assume about 85% of rated capacity is usable after inverter losses. Real results vary with temperature, settings and efficiency.
| Power station | Usable energy | Estimated run time |
|---|---|---|
| EcoFlow DELTA 2 Max surge vs M53 start | 4,800 W surge | Covers about 2,980 VA start |
Watts, amps, volts and kWh in plain English
Watts (W) measure how fast an appliance uses energy right now. Amps (A) measure the current it draws. Volts (V) are the pressure of the supply, about 120 V at a standard US outlet. The link between them is simple: watts = volts x amps. For motors, multiplying volts by amps gives volt-amps (VA), which is slightly higher than real watts because of power factor.
Kilowatt hours (kWh) measure energy over time, and they are what your utility bills you for: kWh = watts x hours / 1,000. A 1,000 W load running for one hour uses 1 kWh. A 50 W load needs 20 hours to use the same 1 kWh. Power stations are rated in watt hours (Wh) of storage and in watts of output; you need enough output watts to start and run the appliance, and enough watt hours to run it for as long as you need.
Sizing worksheet for a generator or power station
- Find the appliance’s running watts (or volts x amps) on its label or in its manual.
- Find its starting (surge) watts. Motors and compressors, such as pumps, freezers and refrigerators, can need two to three times their running power for a moment.
- Add the running watts of everything else you want to power at the same time.
- Choose a generator or power station whose continuous rating covers the running total and whose surge rating covers the largest starting load plus everything else, with about 20 percent margin.
- For a battery, divide its usable watt hours (about 85 percent of the rating) by the average watts to estimate run time.
How it compares with other home appliances
These are the figures from our other “how many watts” guides, all taken from manufacturer specifications:
| Appliance (example model) | Power | Guide |
|---|---|---|
| Top-load washer (Whirlpool WTW5057L) | 290 kWh/year (with electric water heater) | Top-load washer guide |
| Mac mini M4 / RTX 4070 gaming PC | 4-65 W / 650 W PSU | Mac mini M4 / RTX 4070 gaming PC guide |
| 55-inch TV | About 66 W while on | 55-inch TV guide |
| 50 gal electric water heater | 4,500 W at 240 V | 50 gal electric water heater guide |
| 6 qt Instant Pot | 1,000 W | 6 qt Instant Pot guide |
| 5.5 cup rice cooker | 610 W | 5.5 cup rice cooker guide |
| 8,000 BTU window AC | 670 W | 8,000 BTU window AC guide |
| 7 qt slow cooker | 270 W | 7 qt slow cooker guide |
| Electric kettle | 1,500 W | Electric kettle guide |
| Hair dryer | 1,875 W | Hair dryer guide |
| 18.3 cu ft refrigerator | About 47 W average | 18.3 cu ft refrigerator guide |
| Space heater | 1,500 W | Space heater guide |
| CPAP | About 56 W | CPAP guide |
| 7 cu ft chest freezer | About 26 W average | 7 cu ft chest freezer guide |
| 1/3 HP sump pump | About 1,115 VA running | 1/3 HP sump pump guide |
| 1,000 W microwave | 1,500 W input | 1,000 W microwave guide |
Key takeaways
- What is the difference between running watts and starting watts? Running watts keep a device going; starting watts are the short extra burst motors and compressors need to start.
- How many starting watts does a sump pump need? The Zoeller M53 lists 25.9 starting amps, about 2,980 VA, versus about 1,115 VA running.
- Do space heaters need starting watts? No; heating appliances draw about the same power from the first second.
- How do I calculate generator size with starting watts? Add all running watts, then add the extra starting watts of the largest motor, plus about 20% margin.
How to measure your own appliance
Labels show maximum ratings. To see what your appliance really uses, plug it into a plug-in energy meter for a day or a week and read the kWh total. Divide kWh by the hours measured to get the average watts.
Power station used in our examples
Our run-time examples use the EcoFlow DELTA 2 Max: 2048Wh LFP battery, 2,400 W AC output, 4,800 W surge (per EcoFlow). Read our EcoFlow DELTA 2 Max review.
Check the current price on Amazon
Watch: explained in 3D
[Embed the YouTube video here after upload.]
Frequently asked questions
What is the difference between running watts and starting watts?
Running watts keep a device going; starting watts are the short extra burst motors and compressors need to start.
How many starting watts does a sump pump need?
The Zoeller M53 lists 25.9 starting amps, about 2,980 VA, versus about 1,115 VA running.
Do space heaters need starting watts?
No; heating appliances draw about the same power from the first second.
How do I calculate generator size with starting watts?
Add all running watts, then add the extra starting watts of the largest motor, plus about 20% margin.
What happens if starting watts are too high?
The generator’s breaker can trip, voltage can dip, or the motor can fail to start and hum.
Related guides
- What size power station do you need for a refrigerator?
- What size generator do I need for my house?
- Solar generator vs gas generator
- EcoFlow DELTA 2 Max review